摘要:

采用流动注射分析法测定饲料中的亚硝酸盐。线性范围为20~1 000 μg/L,相关系数r=0.999 9;检出限为2.68 μg/L;用50 μg/L亚硝酸钠标准溶液连续测定7次,其相对标准偏差为2.60%;实际样品的加标回收率为82.8%~106.8%。本方法操作简便、灵敏度较高、线性范围宽、精密度高,适用于饲料中亚硝酸盐的测定。

关键词: 流动注射;亚硝酸盐;饲料

Abstract:

Nitrite in feed was determined by flow injection analysis. The linear range was at 20~1000 μg/L, the correlation coefficient r=0.999 9. The detection limit was 2.68 μg/L, the RSD by measuring seven times with the standard solution was 2.60% and the reclaim ratio was 82.8%~106.8%. The method has the characteristics of simplicity, sensitivity, wide linear range and high precision, which is suitable for nitrite determination in feed.

Key words: flow injection analysis, nitrite, feed